New furnace, old chimney: the orphaned water heater problem

It is one of the most common safety issues we find in older Cleveland homes, and most homeowners have never heard of it.

Aluminum chimney liner being lowered into a brick chimney from the roof

What orphaned means

Older homes often vented the furnace and water heater into one chimney. The furnace's hot exhaust kept the chimney warm so both drafted well. Replace the furnace with a 96 percent model and it vents out the side wall. Now the small water heater is alone in a chimney sized for two appliances.

Why it matters

A small amount of warm exhaust in a big, cold chimney cools fast. The draft gets weak, exhaust can spill back into the basement at the draft hood, and moisture condenses inside the chimney, which damages masonry. In the worst cases, carbon monoxide builds up near the water heater.

Old brick chimney base in a basement with a water heater draft hood connected

Signs to look for

Rust or water at the base of the chimney, white staining on the bricks, a draft hood that feels warm and moist, or soot on top of the water heater. A CO alarm in the basement is a must.

The fix

A metal chimney liner sized for the water heater restores proper draft. In some homes, switching to a power-vent or tankless water heater with its own venting is the better move. We test draft and CO before and after so you know it worked.

Need a hand with this? Call (216) 966-0004. We answer 24/7 across Cleveland and 64 nearby areas.