Furnace Replacement in Cleveland, OH

New gas furnaces sized to your house, not guessed from the old label. 80% and 96% units, venting done right, permit pulled.

New high efficiency gas furnace installed in a clean Cleveland basement with white PVC vent pipes and a condensate drain
$4,280 to $9,750Typical range in Cleveland
Quick answer

Replacing a furnace is not just swapping a box. Annwick Heating & Cooling handles furnace replacement across Cleveland and 64 nearby areas, 24/7. Typical cost runs $4,280 to $9,750. Call (216) 966-0004.

What this covers

Replacing a furnace is not just swapping a box. The new unit has to match the duct system, the gas line and the venting. A 96% furnace vents through PVC out the side of the house and needs a drain. An 80% furnace still vents up the chimney, and if it was sharing that chimney with a water heater, the water heater venting has to be checked once the furnace leaves it.

We start with a heat loss estimate for your actual house: square footage, insulation, windows and how drafty it is. A lot of older Cleveland homes have a furnace that is bigger than it needs to be because someone matched the old nameplate. Oversized furnaces short cycle, waste gas and leave the far rooms cold. Getting the size right is the cheapest upgrade there is.

Signs it is time to call

Your furnace is past 18 to 20 years old

Repairs are getting more frequent each winter

A tech has shown you a cracked heat exchanger

Gas bills climb even though you have not changed habits

The house never feels evenly warm

How the visit goes

  1. Heat loss estimate and a look at ducts, gas and venting
  2. Written options with efficiency, size and price
  3. Remove the old unit, set the new one, vent and drain it
  4. Start-up readings, thermostat setup and haul-away

Cleveland notes

In homes built before 1950, which covers much of Cleveland, Lakewood and East Cleveland, we often find the original return air paths were never sized for a forced-air furnace. A replacement is the right time to add a return so the new furnace can breathe.

Close up of blue gas burner flames inside a residential furnace

Typical cost

$4,280 to $9,750

Installed, depending on size, efficiency and venting changes. You get the exact price in writing before any work starts. See the full price list.

Questions

Should I get an 80% or a 96% furnace?

In Northeast Ohio a 96% unit usually pays back because the heating season is long. An 80% unit can make sense in a rental or where PVC venting is hard to route.

How long does a replacement take?

Most furnace swaps take one day. If venting has to move or a return has to be added, plan on a day and a half.

Can I replace the furnace and keep my AC?

Often yes, if the AC coil matches the new furnace cabinet and the AC is not near the end of its life. We check the coil size and refrigerant type before quoting.