Skip to content
(216) 966-0004Answered 24/7

Steam Heating Service in Cleveland, OH

Low-pressure steam systems: banging pipes, cold radiators, spitting vents, low water cutoffs and skimming.

Ornate painted cast iron steam radiator under a window in a historic Cleveland home with a new chrome air vent
$210 to $960Typical range in Cleveland
Quick answer

Steam heat is common in Cleveland's older doubles, apartment buildings and large homes along the east side boulevards. Annwick Heating & Cooling handles steam heating service across Cleveland and 64 nearby areas, 24/7. Typical cost runs $210 to $960. Call (216) 966-0004.

What this covers

Steam heat is common in Cleveland's older doubles, apartment buildings and large homes along the east side boulevards. When it works, it is quiet and even. When it bangs, spits and leaves some rooms cold, the cause is almost always something in the system that can be fixed: a radiator pitched the wrong way, a failed main vent, dirty boiler water or a pressure control set too high.

We service the boiler and the system: skimming oily water, replacing main and radiator air vents, setting the pressuretrol, checking the sight glass and low water cutoff, and re-pitching radiators that trap condensate. A steam system should run at well under 2 psi.

Signs it is time to call

Loud banging or hammering in the pipes

Water level in the sight glass bounces wildly

Radiator vents hiss constantly or spit water

Some radiators get hot hours after others

The boiler needs water added every week

How the visit goes

  1. Check pressure control, sight glass and low water cutoff
  2. Skim or flush the boiler water
  3. Replace failed main and radiator vents
  4. Pitch radiators and confirm even heat across the house

Cleveland notes

Steam houses in Glenville, Buckeye-Shaker and Cleveland Heights often had their main vents painted over or removed decades ago. Restoring proper main venting is the single repair that most often quiets the pipes and evens out the heat.

Technician inspecting a furnace heat exchanger with a flashlight and mirror

Typical cost

$210 to $960

Vents, skimming and controls. Re-piping is quoted on site. You get the exact price in writing before any work starts. See the full price list.

Questions

Why do my steam pipes bang?

Water is trapped where steam travels. Usually a radiator or pipe is pitched wrong, or the boiler water is dirty and surging.

How often should steam boiler water be checked?

Look at the sight glass weekly in winter. If you add water often, call us, because the system is losing steam somewhere.

Can steam heat be made more efficient?

Yes. Proper venting, a lower pressure setting and an insulated main can cut fuel use noticeably.

Heating

Related heating services

Where we do steam heating service

Heat out or AC down? Call now.

A real person answers (216) 966-0004 every hour of every day.