What the switch checks
Before the burners light, the inducer motor starts and pulls air through the heat exchanger and out the vent. The pressure switch confirms that draft is there. No draft, no ignition. It is a safety device that keeps exhaust from spilling into the house.
The usual causes
A blocked vent outside, often snow or ice. Water sitting in a sagging vent pipe or a clogged trap. A cracked or disconnected hose between the switch and the inducer. An inducer motor that is slowing down with age. Less often, the switch itself has failed.

What you can check
Look at the PVC vents outside for snow, ice or a nest. Listen at the furnace: if the inducer hums or rattles loudly, it may be failing. Do not bypass or jumper the switch. That defeats a safety device and can let exhaust into the home.
What we do
We measure the actual draft with a manometer, check the hoses and trap, test the inducer and look at the vent slope. Most pressure switch calls end with a cleared trap, a hose or an inducer, not a new furnace.