Why a furnace makes water
A 90 percent or higher furnace pulls so much heat out of its exhaust that the water vapor in it condenses. A typical furnace can make a few gallons a day in January. That water runs through a plastic trap and a small drain line to a floor drain, a sink or a condensate pump.
Where the freeze happens
Drains that leave the house through a rim joist or run along an outside wall are the usual problem. So are drain lines that pass through an unheated crawlspace or garage. Once the water stops moving, it backs up into the trap, a pressure switch senses it and the furnace shuts down to protect itself. Some furnaces show a pressure switch code. Others just try, fail and try again.

A safe thaw
Turn the furnace off at its switch. Find the drain line and follow it to where it is cold. Warm the frozen section with a hair dryer or warm towels, never an open flame or a heat gun on PVC. Once water flows, turn the furnace back on. If it starts and keeps running, you found it.
Stopping it for good
The real fix is to keep the drain inside heated space: reroute it to a floor drain, add a condensate pump inside the basement, or insulate and heat-trace the run when there is no other path. We do all three, and it is usually a short visit.