First, make sure it is hot water
Hot water radiators have a small square or slotted valve near the top on one end. Steam radiators have a larger air vent, often chrome, sticking out the side. Do not open a steam vent. This guide is only for hot water systems.
What you need
A radiator key from any hardware store (some valves take a flat screwdriver), a rag and a small cup.

The steps
Let the heat run so the system is warm. Start with the radiator closest to the boiler on the lowest floor and work up and away. Hold the rag under the valve and turn the key a quarter turn. You will hear hissing. When a steady stream of water comes out with no sputtering, close the valve. Move to the next radiator.
Check the pressure after
Bleeding lets a little water out. Look at the gauge on the boiler. Most homes run between 12 and 20 psi when cold. If it is well below that, the boiler may need water added, and if you have to bleed every week, something is letting air in. That is when to call us.