What defrost is
In heating mode, the outdoor coil runs colder than the outside air, so moisture freezes on it. Every so often, the heat pump switches into cooling mode for a few minutes to warm the coil and melt the frost. The outdoor fan stops during this time.
What is normal
A whoosh when the reversing valve switches, a cloud of steam rising off the unit, water draining underneath, and a few minutes of cooler air from the vents if there is no backup heat on. All normal.

What is not
A coil that stays covered in solid ice for hours, ice building up from the bottom, a fan that keeps running with ice on the coil, or a unit that never seems to defrost. Those point to a failed defrost sensor or board, low refrigerant, or water dripping onto the unit from the roof.
Placement matters
Outdoor units should sit on a stand above the snow line and out from under roof edges without gutters. Melt water needs somewhere to drain without refreezing around the base.